ABOUT US
Adhering to the spirit of "specialization and focus", we provide ingenious products to serve millions of users worldwide

The quality and technology supervision bureaus (market supervision and administration departments) of all provinces, autonomous regions, municipalities directly under the Central Government and Xinjiang Production and Construction Corps:
In accordance with the provisions of the Product Quality Law of the People's Republic of China and the Administrative Measures for Product Quality Supervision and Spot Check, in 2016, the AQSIQ organized a special national supervision and spot check on air purifier products (hereinafter referred to as "special spot check"). The relevant situation is hereby reported as follows:
1、 Basic information
This time, 61 batches of products produced by 56 enterprises in 8 provinces (cities) were randomly inspected, and 21 items were tested in three aspects: safety indicators, performance indicators, and electromagnetic compatibility indicators. After inspection, 46 batches of products from 42 enterprises were found to be qualified, with a spot check qualification rate of 75.4%. The 15 batches of products produced by 14 enterprises are unqualified, and the detection rate of unqualified products is 24.6%. According to the production scale of enterprises, the number of large, medium, and small enterprises in this spot check accounted for 48.2%, 25%, and 26.8% of the total number of enterprises in the spot check, respectively. The detection rates of unqualified products were 10%, 43.7%, and 33.3%, respectively.
2、 Main features
One is to cover well-known brands. This spot check is a national supervision spot check on air purifiers, covering well-known brand enterprises in the industry, with nearly one fifth of the total number of production enterprises in the country being inspected. In this random inspection, the number of large enterprises accounted for about half of the total number of sampled enterprises, and the product qualification rate of large enterprises reached 90%.
The second is to compare performance indicators. In conjunction with the improvement of consumer product quality, testing and comparison of product performance indicators will be carried out while conducting spot checks. Six core performance indicators, including particulate matter clean air volume (CADR), formaldehyde clean air volume (CADR), particulate matter purification energy efficiency (efficiency), formaldehyde purification energy efficiency (efficiency), cumulative particulate matter purification amount (CCM), and noise, will be tested for all sampled products, and ranked according to individual test values, Guide consumers to make scientific and reasonable product choices.
Thirdly, pay attention to the implementation of the new national standard. Among the 61 batches of products sampled in this inspection, 35 batches of products comply with the new national standard GB/T 18801-2015 "Air Purifiers" implemented on March 1, 2016, accounting for 57.4% of the total number of products sampled. For products that have not implemented the new national standards, their performance indicators shall be determined according to the execution standards and explicit quality requirements of the sampled products.
The fourth is to highlight spot checks on concentrated production areas. This spot check conducted on products from industrial clusters in Shanghai, Jiangsu, Zhejiang, Guangdong, and other regions. The pass rate of product spot checks in both Zhejiang and Guangdong provinces exceeded 85%, while the pass rate of product spot checks in Shanghai and Jiangsu provinces was below the average pass rate level of this spot check.
3、 Analysis of spot check results
In this special spot check, the protection against contact with live parts, input power and current, leakage current and electrical strength at working temperature, moisture resistance, leakage current and electrical strength, stability and mechanical hazards, structure, internal wiring, components, power connections and external flexible wires, grounding measures, radiation toxicity and similar hazards, harmful substance release, particulate matter clean air volume, formaldehyde clean air volume 21 projects, including cumulative purification amount of particulate matter, energy efficiency (efficiency) of particulate matter purification, energy efficiency (efficiency) of formaldehyde purification, noise, continuous disturbance voltage, and continuous disturbance power.
After inspection, the main quality issues of unqualified products involve three aspects: safety indicators, performance indicators, and electromagnetic compatibility indicators, mainly including protection against touching live parts, leakage current and electrical strength at working temperature, leakage current and electrical strength, stability and mechanical hazards, internal wiring, components, power connections, and external flexible cables, particle cleaning clearance, and cumulative purification of particles A total of 13 items, including formaldehyde purification efficiency (purification efficiency), noise, continuous disturbance voltage, and continuous disturbance power, were found to be unqualified.
One issue is the non-compliance of electrical safety projects. One batch of protection against contact with live parts is unqualified, three batches of leakage current and electrical strength at operating temperature are unqualified, one batch of leakage current and electrical strength is unqualified, one batch of stability and mechanical hazards is unqualified, one batch of internal wiring is unqualified, two batches of components are unqualified, and three batches of power connections and external flexible wires are unqualified.
The second issue is the issue of unqualified performance items. There are 2 batches of unqualified clean air volume for particulate matter, 1 batch of unqualified cumulative purification volume for particulate matter, 3 batches of unqualified energy efficiency (efficiency) for formaldehyde purification, and 5 batches of unqualified noise.
The third issue is the non-compliance of electromagnetic compatibility projects, with 8 batches of continuous disturbance voltage and 4 batches of continuous disturbance power.
4、 Job requirements
In view of the problems found in the national supervision and spot check of product quality, the quality and technical supervision departments (market supervision and management departments) of all provinces (regions and cities) should carefully handle the post processing work in accordance with the Product Quality Law of the People's Republic of China, the Administrative Measures for Product Quality Supervision and Spot Check and other laws and regulations:
(1) For production enterprises with substandard product quality in this random inspection, post-processing work should be carried out in accordance with the law. Order enterprises to stop producing and selling unqualified products in accordance with the law, and supervise the destruction or necessary technical treatment in accordance with relevant regulations.
(2) In response to the outstanding quality issues reflected in this random inspection, such as leakage current and electrical strength at working temperature, formaldehyde purification energy efficiency (efficiency), noise, continuous disturbance voltage, continuous disturbance power, etc., it is necessary to increase the follow-up tracking, supervision and inspection efforts on production enterprises.
(3) Inform the local government and relevant departments of the unqualified products in this spot check, take effective measures to urge enterprises to implement the main responsibility of product quality and safety according to law, guide enterprises to organize production in strict accordance with Standards organization, and effectively maintain product quality and safety.
Attachment:
1. 2016 National Supervision Special Spot Check Results of Air Purifier Product Quality
2. 2016 Air Purifier Spot Check Performance Index Comparison Results - Particle Clean Air Volume (CADR)
3. 2016 Air Purifier Spot Check Performance Index Comparison Results - Formaldehyde Clean Air Volume (CADR)
4. 2016 Air Purifier Spot Check Performance Index Comparison Results - Particle Purification Energy Efficiency (Efficiency)
5. 2016 Air Purifier Spot Check Performance Index Comparison Results - Formaldehyde Purification Energy Efficiency (Efficiency)
6. Performance Index Comparison Results of Air Purifier Spot Check in 2016- Accumulated Particle Purification (CCM)
7. 2016 Air Purifier Spot Check Performance Index Comparison Results - Noise
8. List of Enterprises Implementing National Standard GB/T 18801-2015 for Air Purifier Spot Check Products in 2016
9. Consumer Guidelines
+8613298336026